Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Appl Bio Mater ; 7(2): 990-998, 2024 Feb 19.
Article in English | MEDLINE | ID: mdl-38226433

ABSTRACT

Catheter-associated urinary tract infections (CAUTI) are among the most common bacterial infections associated with prolonged hospitalization and increased healthcare expenditures. Despite recent advances in the prevention and treatment of these infections, there are still many challenges remaining, among them the creation of a durable catheter coating, which prevents bacterial biofilm formation. The current work reports on a method of protecting medical tubing endowed with antibiofilm properties. Silicone catheters coated sonochemically with ZnO nanoparticles (NPs) demonstrated excellent antibiofilm effects. Toward approval by the European Medicines Agency, it was realized that the ZnO coating would not withstand the regulatory requirements of avoiding dissolution for 14 days in artificial urine examination. Namely, after exposure to urine for 14 days, the coating amount was reduced by 90%. Additional coatings with either carbon or silica maintained antibiofilm activity against Staphylococcus aureus while resisting dissolution in artificial urine for 14 days (C- or SiO2-protected catheters exhibited only 29% reduction). HR-SEM images of the protected catheters indicate the presence of the ZnO coating as well as the protective layer. Antibiofilm activity of all catheters was evaluated both before and after exposure to artificial urine. It was shown that before artificial urine exposure, all coated catheters showed high antibiofilm properties compared to the uncoated control. Exposure of ZnO-coated catheters, without the protective layer, to artificial urine had a significant effect exhibited by the decrease in antibiofilm activity by almost 2 orders of magnitude, compared to unexposed catheters. Toxicity studies performed using a reconstructed human epidermis demonstrated the safety of the improved coating. Exposure of the epidermis to ZnO catheter extracts in artificial urine affects tissue viability compared with control samples, which was not observed in the case of ZnO NPs coating with SiO2 or C. We suggest that silica and carbon coatings confer some protection against zinc ions release, improving ZnO coating safety.


Subject(s)
Bathroom Equipment , Zinc Oxide , Humans , Zinc Oxide/pharmacology , Silicon Dioxide/pharmacology , Biofilms , Anti-Bacterial Agents/pharmacology , Catheters , Carbon
2.
Small ; 18(7): e2104625, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34882972

ABSTRACT

High-Ni-rich layered oxides [e.g., LiNix Coy Mnz O2 ; x > 0.5, x + y + z = 1] are considered one of the most promising cathodes for high-energy-density lithium-ion batteries (LIB). However, extreme electrode-electrolyte reactions, several interfacial issues, and structural instability restrict their practical applicability. Here, a shortened unconventional atomic surface reduction (ASR) technique is demonstrated on the cathode surface as a derivative of the conventional atomic layer deposition (ALD) process, which brings superior cell performances. The atomic surface reaction (reduction process) between diethyl-zinc (as a single precursor) and Ni-rich NMC cathode [LiNi0.8 Co0.1 Mn0.1 O2 ; NCM811] material is carried out using the ALD reactor at different temperatures. The temperature dependency of the process through advanced spectroscopy and microscopy studies is demonstrated and it is shown that thin surface film is formed at 100 °C, whereas at 200 °C a gradual atomic diffusion of Zn ions from the surface to the near-surface regions is taking place. This unique near-surface penetration of Zn ions significantly improves the electrochemical performance of the NCM811 cathode. This approach paves the way for utilizing vapor phase deposition processes to achieve both surface coatings and near-surface doping in a single reactor to stabilize high-energy cathode materials.

3.
ACS Appl Mater Interfaces ; 13(30): 36416-36425, 2021 Aug 04.
Article in English | MEDLINE | ID: mdl-34296861

ABSTRACT

Production of multilayered microstructures composed of conducting and insulating materials is of great interest as they can be utilized as microelectronic components. Current proposed fabrication methods of these microstructures include top-down and bottom-up methods, each having their own set of drawbacks. Laser-based methods were shown to pattern various materials with micron/sub-micron resolution; however, multilayered structures demonstrating conducting/insulating/conducting properties were not yet realized. Here, we demonstrate laser printing of multilayered microstructures consisting of conducting platinum and insulating silicon oxide layers by a combination of thermally driven reactions with microbubble-assisted printing. PtCl2 dissolved in N-methyl-2-pyrrolidone (NMP) was used as a precursor to form conducting Pt layers, while tetraethyl orthosilicate dissolved in NMP formed insulating silicon oxide layers identified by Raman spectroscopy. We demonstrate control over the height of the insulating layer between ∼50 and 250 nm by varying the laser power and number of iterations. The resistivity of the silicon oxide layer at 0.5 V was 1.5 × 1011 Ωm. Other materials that we studied were found to be porous and prone to cracking, rendering them irrelevant as insulators. Finally, we show how microfluidics can enhance multilayered laser microprinting by quickly switching between precursors. The concepts presented here could provide new opportunities for simple fabrication of multilayered microelectronic devices.

4.
ACS Omega ; 5(31): 19409-19421, 2020 Aug 11.
Article in English | MEDLINE | ID: mdl-32803034

ABSTRACT

We report a facile two-furnace APCVD synthesis of 2H-WSe2. A systematic study of the process parameters is performed to show the formation of the phase-pure material. Extensive characterization of the bulk and exfoliated material confirm that 2H-WSe2 is layered (i.e., 2D). X-ray diffraction (XRD) confirms the phase, while high-resolution scanning electron microscopy (HRSEM), high-resolution transmission electron microscopy (HRTEM), and atomic force microscopy (AFM) clarify the morphology of the material. Focused ion beam scanning electron microscopy (FIB-SEM) estimates the depth of the 2H-WSe2 formed on W foil to be around 5-8 µm, and Raman/UV-vis measurements prove the quality of the exfoliated 2H-WSe2. Studies on the redox processes of lithium-ion batteries (LiBs) show an increase in capacity up to 500 cycles. On prolonged cycling, the discharge capacity up to the 50th cycle at 250 mA/g of the material shows a stable value of 550 mAh/g. These observations indicate that exfoliated 2H-WSe2 has promising applications as an LiB electrode material.

5.
Proc Natl Acad Sci U S A ; 115(23): E5419-E5428, 2018 06 05.
Article in English | MEDLINE | ID: mdl-29784829

ABSTRACT

Thousands of specialized, steroidal metabolites are found in a wide spectrum of plants. These include the steroidal glycoalkaloids (SGAs), produced primarily by most species of the genus Solanum, and metabolites belonging to the steroidal saponins class that are widespread throughout the plant kingdom. SGAs play a protective role in plants and have potent activity in mammals, including antinutritional effects in humans. The presence or absence of the double bond at the C-5,6 position (unsaturated and saturated, respectively) creates vast structural diversity within this metabolite class and determines the degree of SGA toxicity. For many years, the elimination of the double bond from unsaturated SGAs was presumed to occur through a single hydrogenation step. In contrast to this prior assumption, here, we show that the tomato GLYCOALKALOID METABOLISM25 (GAME25), a short-chain dehydrogenase/reductase, catalyzes the first of three prospective reactions required to reduce the C-5,6 double bond in dehydrotomatidine to form tomatidine. The recombinant GAME25 enzyme displayed 3ß-hydroxysteroid dehydrogenase/Δ5,4 isomerase activity not only on diverse steroidal alkaloid aglycone substrates but also on steroidal saponin aglycones. Notably, GAME25 down-regulation rerouted the entire tomato SGA repertoire toward the dehydro-SGAs branch rather than forming the typically abundant saturated α-tomatine derivatives. Overexpressing the tomato GAME25 in the tomato plant resulted in significant accumulation of α-tomatine in ripe fruit, while heterologous expression in cultivated eggplant generated saturated SGAs and atypical saturated steroidal saponin glycosides. This study demonstrates how a single scaffold modification of steroidal metabolites in plants results in extensive structural diversity and modulation of product toxicity.


Subject(s)
Alkaloids/biosynthesis , Saponins/biosynthesis , Solanaceae/chemistry , Alkaloids/chemistry , Gene Expression Regulation, Plant/genetics , Glycosides/biosynthesis , Glycosides/chemistry , Solanum lycopersicum/enzymology , Solanum lycopersicum/genetics , Solanum lycopersicum/metabolism , Oxidoreductases/metabolism , Plant Extracts/chemistry , Plants, Genetically Modified/metabolism , Saponins/chemistry , Saponins/metabolism , Solanaceae/metabolism , Steroids/chemistry , Tomatine/analogs & derivatives , Tomatine/metabolism
6.
Biosens Bioelectron ; 45: 201-5, 2013 Jul 15.
Article in English | MEDLINE | ID: mdl-23500364

ABSTRACT

Microelectronic-based sensors are ideal for real-time continuous monitoring of health states due to their low cost of production, small size, portability, and ease of integration into electronic systems. However, typically semiconductor-based devices cannot be operated in aqueous solutions, especially in solutions with a low pH. However, in this work we overcame this difficulty and demonstrated the feasibility of a hemoglobin sensing array based on hybrid organic GaAs-based devices, which can remain in biological solutions for more than 24h. This was achieved by coating devices with a nanometer-thick polymer protective layer with subsequent adsorption of antibodies on its surface. The device is capable of functioning even in harsh physiological fluids, such as urine and bile juice. The surface modification allows a change in electrical potential, created by the interaction, to be efficiently transferred to the surface of the semiconductor device. By utilizing an array configuration, it is possible to obtain high sensitivity and selectivity.


Subject(s)
Biosensing Techniques , Hemoglobins/isolation & purification , Quantum Dots , Antibodies/immunology , Antibodies/isolation & purification , Arsenicals/chemistry , Gallium/chemistry , Hemoglobins/immunology , Hemoglobins/metabolism , Humans , Hydrogen-Ion Concentration , Organic Chemicals , Surface Properties
7.
Langmuir ; 28(1): 1020-8, 2012 Jan 10.
Article in English | MEDLINE | ID: mdl-22126281

ABSTRACT

The detection of covalent and noncovalent binding events between molecules and biomembranes is a fundamental goal of contemporary biochemistry and analytical chemistry. Currently, such studies are performed routinely using fluorescence methods, surface-plasmon resonance spectroscopy, and electrochemical methods. However, there is still a need for novel sensitive miniaturizable detection methods where the sample does not have to be transferred to the sensor, but the sensor can be brought into contact with the sample studied. We present a novel approach for detection and quantification of processes occurring on the surface of a lipid bilayer membrane, by monitoring the current change through the n-type GaAs-based molecularly controlled semiconductor resistor (MOCSER), on which the membrane is adsorbed. Since GaAs is susceptible to etching in an aqueous environment, a protective thin film of methoxysilane was deposited on the device. The system was found to be sensitive enough to allow monitoring changes in pH and in the concentration of amino acids in aqueous solution on top of the membrane. When biotinylated lipids were incorporated into the membrane, it was possible to monitor the binding of streptavidin or avidin. The device modified with biotin-streptavidin complex was capable of detecting the binding of streptavidin antibodies to immobilized streptavidin with high sensitivity and selectivity. The response depends on the charge on the analyte. These results open the way to facile electrical detection of protein-membrane interactions.


Subject(s)
Membranes, Artificial , Semiconductors
SELECTION OF CITATIONS
SEARCH DETAIL
...